Test of DC-DC 7A 9-60V to 3-32V
This document has all the test I performed.
For the actual review see here
Contents
Load sweep 5V output load
Load sweep 12V output load
Load sweep 24V output load
Load sweep 32V output load
Voltage sweep 5V output load
Voltage sweep 12V output load
Voltage sweep 24V output load
Voltage sweep 32V output load
Voltage sweep no load
Noise 5V output
Noise 12V output
Noise 32V output
On/off
Load test with thermophotos
Load sweep 5V output load
Load sweep 12V output load
Load sweep 24V output load
Load sweep 32V output load
Voltage sweep 5V output load
Voltage sweep 12V output load
Voltage sweep 24V output load
Voltage sweep 32V output load
Voltage sweep no load
Noise 5V output
Noise 12V output
Noise 32V output
On/off
On/off test are done with a fast mos switch and power resistors. The current clamp used is not rated for these fast signals, but it was useful for triggering the scope and showing the load current, but not the transition.
Load test with thermophotos
M1: 52.1°C, HS1: 66.2°C
M1: 50.2°C, HS1: 91.3°C
M1: 53.0°C, HS1: 98.7°C
M1: 60.3°C, M2: 73.8°C, HS1: 90.2°C
M1: 66.6°C, HS1: 87.8°C
M1: 87.5°C, HS1: 157.2°C
M1: 63.5°C, HS1: 141.9°C
M1: 97.7°C, M2: 103.4°C, HS1: 151.3°C