DMM Aneng AN882B+

DSC_2965

This is a cheap DMM from Aneng, it looks like a downgraded version of AN860B+.
The meter is sold with either red, green or blue sleeve.

DSC_2948 DSC_2949 DSC_2952 DSC_2953

The box is not for this meter and it looks like it got a hard treatment during shipping.

DSC_2954

In the box was the meter, standard probes, probes with replace tips, thermocoupler and a manual.
The manual is fairly generic and the same is the specifications, i.e. it do not match this meter fully.

DSC_2959
DSC_2960
DSC_2961

The CAT III rating on the probe is not correct due to the long metal tip.

DSC_2962

The shroud is a short one.

DSC_2957

DSC_2958

The other probe set is with removable accessories, the probe wires have threads at both ends.

DSC_2956

And these accessories can be used to build the desired combination.

DSC_2963
DSC_2964

The thermocoupler is a cheap model with banana plugs.

DSC_2970 DSC_2977

When using the tilting bale the meter is nearly stable enough to turn the switch and push the buttons (If placed on a non-slip surface it will probably be stable enough).

DSC_2966

DSC_2967 DSC_2968

DSC_2969

DSC_2986

DSC_2987

DSC_2988

DSC_2989 DSC_2990

DSC_2991

DSC_2971

DSC_2972

I was a bit surprised about the batteries, the back says a 9V battery.



Display

DSC_2975

The above picture shows all the segments on the display. Not all the segments are used on this meter.

DSC_2976

Typical display with value and range.



Functions

DSC_2978

Buttons: Rotary switch:
Input

DSC_2979



Measurements 1uF

A look at the capacitance measurement waveform.

DMMInputVoltageSweepHz

Frequency input resistance depends on input voltage.

DMMInputVoltageSweepmVDC

mV DC is high input impedance up to about 2V

400mA

With 400mA on the 600mA range the burden voltage is around 3V and after 10-15 seconds the PTC heats up.

600mA

At 600mA the burden voltage is around 4.5V and you have 4-6 seconds before the PTC heats up.

DMMschema

mA range uses a PTC as fuse and it trips below 600mA
uF ranges are at the limit of specified tolerance.



Tear down

DSC_2992

I had to remove the battery cover, the sleeve and four screws to open the meter.

DSC_2993

DSC_2994

The circuit board is fairly small.

DSC_2995

DSC_2996

I had to remove four screws from the circuit board to get it out.

DSC_2997

DSC_3001

The current input is the usual wire resistor for 10A, this one is fairly large (good) and two resistors for uA and mA (R37 & R52: 99ohm & 0.99ohm), these two resistors are protected by some diodes (D9, D10, D11, D12, D??) and a PTC (FUSE: GR265-200), I wonder if the 200 means 200mA rating? The 10A range is without a fuse.
The voltage input uses four resistors (R44..R47: 4x2.5Mohm), mV, Hz, temperature uses the PTC together with a transistor pair (Q3 & Q4) for input. In ohms this is output and input is trough a small SMD resistor (R43: 900kOhm).
The actual multimeter chip is hidden beneath the black blob (IC5: COP) with a EEPROM (24C02A) next to it.

DSC_3002

DSC_3003 DSC_3005

DSC_3004

DSC_2999

This side only has pads for the rotary switch, the buttons and the LCD display.

DSC_3000



Conclusion

This meter is very far from its CAT rating with no 10A fuse and fraudulent markings on the front saying there is one.
The meter measures fine enough, except on the capacity range where the calibration is borderline on many of the ranges. There is the problem with the mA PTC fuse being rated for much lower current than the mA range, the PTC also means a fairly high burden voltage when nearing the trip current.

The meter has a good selection of ranges, but no extra functions and with the above problems I would suggest getting another meter.



Notes

This meter may exist with many different names on it and small variations in functions.

How do I review a DMM